Multiple printer options.Automatic Measurements SEGMENT, COUNT/SIZE, CLASSIFY, and ANALYZE Linux operating system, 10,000 specimen storage with graphics, 25 QC files each with 120 data points. Immuno T-Cell (CD3/4/8) reagent Immuno Plt (CD61) assayĠ.0-250.0 x 10 3/μL (No interference of HGB) Patented RNA fluorescent flow cytometry, random and continuous access
#Processing of cell count by image pro plus plus#
We provide a comprehensive, proactive diagnostics service plan, backed by our 125-year history and robust ecosystem of people, processes and technology that helps keep your hematology system up and running.Ĥ angle optical MAPSS plus 3-color fluorescent flow cytometry, Multiple Scatterplot AnalysisĤ angle optical MAPSS plus red fluorescence no extra reagent, no reflex testing requirement Multiple Scatterplot Analysisĭual angle optical analysis, no extra reagent, no reflex testing requirement You also get the company and people behind it - Abbott Diagnostics. The CELL-DYN Sapphire seamlessly integrates with other Abbott diagnostics systems, making it an optimal instrument for today’s connected laboratories. These specialty tests can be performed without any additional equipment, utilizing only 4-5 reagents, further maximizing efficiencies for laboratories A Trusted partner for integrated laboratories OpenFlow assays for WBC, RBC, and/or PLT (RUO) allow you the flexibility to expand laboratory offerings to include others tests that may normally require a specialty laboratory.Ĭonfidence in results for normal and speciality testsĬELL-DYN Sapphire offers an expanded test menu beyond the traditional CBC, enabling your medical technologists the flexibility to handle a breadth of samples and specialty tests. OpenFlow Assays can be added to the menu, using fluorescence and light scatter plus monoclonal antibodies from a third party. Menu expansion with Open Flow Monoclonal Assays The CELL-DYN Sapphire is also capable of accurately performing the common flow cytometry panel CD3/4/8 with automated gating, which not only moves a specialty test into routine laboratory operations available on-demand, but also makes room in the flow cytometry laboratory to focus on more specialty testing.
Confirmation at the critical medical decision point ensures that your patients get the transfusions they need. When the need for low-end platelet accuracy is paramount, clinicians can depend on the gold standard CD61 analysis provided by the CELL-DYN Sapphire.
Confident Transfusions with CD61 Analysis Optical platelets are obtained through dual angle laser analysis, providing separation from RBCs and other interferences, giving you confidence in your results. NRBCs are measured by DNA fluorescence and require no correction for the WBC count. With no additional reagents, reportable NRBCs and optical platelets are included with each and every CBC. Reliable NRBCs and Optical Platelets on First Pass While some systems can require as many as 12 reagents for standard tests, the CELL-DYN Sapphire can run most tests with only 4-5 reagents, improving laboratory efficiency and helping to manage costs. Only 4-5 Required Reagents for Laboratory Efficiency Our Multi Angle Polarized Scatter Separation (MAPSS) technology, only available with CELL-DYN analyzers, delivers first pass WBC and differential results by using laser measurement of up to 20,000 WBCs with four angles of optical analysis from a single dilution.Įven when WBC counts are critically low, you can rely on the extended WBC mode to still deliver a 5-part differential.
Proprietary MAPSS Technology Delivers Robust Results